Schertz, TX · Furnace parts

Furnace gas valve replacement in Schertz

The igniter glows bright orange, but the burners never light? If the gas supply is on, a failed furnace gas valve may be the reason. It's a repair that always calls for a licensed technician.

Smell gas? Leave the home immediately and call 911 or your gas utility's emergency line from outside. Don't touch the furnace, switches or phones inside.

What the gas valve does

The furnace gas valve controls the flow of natural gas (or propane) to the burners. When the control board confirms the inducer is running, the draft is safe and the igniter is hot, it sends 24 volts to the valve, which opens and regulates gas to a precise pressure. Modern valves contain redundant safety shutoffs, so gas only flows when every condition is met.

There are three main types:

  • Single-stage: fully open or closed. Most standard furnaces.
  • Two-stage: low fire for mild days, high fire for cold ones. Quieter and more even heat.
  • Modulating: adjusts in small increments on premium furnaces.

Signs of a failing gas valve

  • The igniter glows, but no gas flows and the burners don't light
  • The furnace locks out after several failed ignition attempts
  • The burners light weakly or the flame is noticeably small (low outlet pressure)
  • The burners won't shut off when the thermostat is satisfied, which is a serious fault
  • A gas smell near the furnace

Gas valve or something else?

Gas valves fail less often than igniters and flame sensors, so a good diagnosis rules out the common causes first:

  1. Is gas reaching the furnace? Check the manual shutoff valve, other gas appliances, and the meter. For propane, check the tank level.
  2. Is the valve getting 24 volts during the ignition step? No voltage points to the control board or a safety switch.
  3. Does the valve open with voltage present? If 24V reaches it and gas doesn't flow, the valve has failed.
  4. Are inlet and outlet pressures correct? These are measured with a manometer.

Why this is never a DIY repair

Replacing a gas valve means disconnecting and reconnecting gas piping, leak-testing every joint, and setting the outlet pressure to the manufacturer's specification with a manometer. Pressure that's too high can overheat the heat exchanger. Too low causes poor combustion and condensation in the heat exchanger. In Texas, this work should be done by a licensed HVAC contractor.

After replacement

We leak-test all connections, set and verify the gas pressure, check flame quality and run a combustion test to confirm safe operation before leaving.

Gas valve replacement cost

Typical gas valve costs in SchertzParts and labor, Schertz / San Antonio area, 2026 estimates. You get an exact written price before work begins.
Item Typical cost Notes
Single-stage gas valve, installed $300 – $650 Most standard furnaces
Two-stage gas valve, installed $450 – $850 Two-stage furnaces
Modulating / OEM-specific valve $600 – $1,000+ Premium furnaces
Gas pressure check and adjustment $100 – $200 When the valve itself is fine
FAQ

Gas Valve Replacement FAQs

Don't see your question? Call (210) 898-9282.

How do I know if my furnace gas valve is bad?

The clearest sign is an igniter that glows while no gas reaches the burners, with gas service confirmed on. A technician confirms by checking for 24 volts at the valve and measuring gas pressure.

Can a gas valve leak?

Yes. Connections can leak, and in rare cases the valve body can too. Any gas smell should be treated as an emergency: leave the home and call from outside.

How long does a furnace gas valve last?

Often the life of the furnace, 15–20 years or more. Failures are less common than igniter or flame sensor problems.

Furnace down? Get your heat back today.