CO alarm, exhaust smell, or a vent pipe that's fallen apart in the attic? Turn the furnace off. If anyone feels ill or an alarm is sounding, get outside and call 911.
Two kinds of furnace venting
80% furnaces: metal flue
Hot exhaust rises through double-wall metal pipe (B-vent) and out a roof cap. It must slope upward and keep required clearances from wood and insulation.
90%+ furnaces: PVC pipes
Cooler exhaust is pushed out through plastic pipe, often with a second pipe bringing in combustion air. Exhaust pipes slope back toward the furnace so condensate drains.
Common venting problems in Schertz homes
- Disconnected or separated joints in the attic. Pipes get bumped during other attic work or sag over time. A disconnected flue can vent exhaust into the attic.
- Nests and debris. Birds and wasps build in vent terminations, especially PVC pipes on sidewalls and roofs after the furnace sits idle all summer.
- Improper slope. PVC exhaust sloped the wrong way traps condensate, causing gurgling and pressure-switch lockouts.
- Roof work damage. Roofers replacing shingles after hailstorms sometimes damage or reconnect flue caps and roof jacks incorrectly.
- Rusted or deteriorated metal flue on older systems.
- Shared flue issues when a gas water heater vents into the same flue, especially after one appliance is replaced.
Signs of a venting problem
- Pressure-switch error codes or a tripped rollout switch
- An exhaust or "chemical" smell when the furnace runs
- Gurgling or water sounds in the PVC pipe
- Rust, soot or water stains around the flue where it leaves the furnace
- A carbon monoxide alarm
What we inspect and repair
- Trace the full vent run from furnace to termination, including the attic and the roof cap.
- Check joints, supports, slope and clearances against the manufacturer's installation instructions and code.
- Clear blockages at terminations and install screens or guards where appropriate.
- Measure draft and run a combustion test to confirm exhaust is leaving the home properly.
- Repair or replace damaged sections with the correct material for your furnace.
If we find venting problems along with a damaged heat exchanger or chronic rollout trips, we'll explain how they're connected.
Flue and venting repair cost
| Item | Typical cost | Notes |
|---|---|---|
| Vent termination clearing | $150 – $300 | Nests and debris, with guard install |
| Reconnect / secure attic flue joints | $150 – $400 | Includes draft and CO test |
| Re-slope or replace PVC venting | $300 – $800 | Depends on length and access |
| Metal flue section replacement | $300 – $800 | Rusted or damaged B-vent |