The safety switches in your furnace
Pressure switch
Confirms the inducer has created a safe draft before ignition is allowed. A rubber tube connects it to the inducer or the condensate collector box.
High limit switch
Shuts off the burners if the air around the heat exchanger gets too hot, usually because air isn't moving through the furnace fast enough.
Rollout switch
Trips if flames roll out of the burner area. Usually it must be reset by hand, and it signals a serious problem like a blocked flue or heat exchanger.
Auxiliary limit
Found on some furnaces near the blower. Protects against overheating if the blower fails.
Pressure switch problems
Symptoms: the inducer runs, but the igniter never glows, and the board flashes a "pressure switch open" code.
What usually causes it:
- A clogged condensate trap or drain on high-efficiency furnaces. Water backs up and blocks the pressure port. This is the number one cause in Schertz attic furnaces.
- Cracked, kinked or water-filled tubing between the switch and the inducer
- A blocked vent or intake pipe: bird or wasp nests, debris, or a disconnected PVC joint
- A weak inducer motor that can't build enough draft
- A failed switch, which happens, but less often than the causes above
Limit switch problems
Symptoms: the furnace lights and heats, then shuts off mid-cycle while the blower keeps running, then restarts later. You may notice it short cycling.
What usually causes it:
- A clogged filter. By far the most common cause, and worse during mountain cedar season. Check this first.
- Closed or blocked supply vents and returns (furniture, rugs, closed doors to rooms with returns)
- A dirty blower wheel or failing blower motor
- Undersized or crushed ductwork, common with attic flex ducts
- A weak switch that trips below its rated temperature
Repeated limit trips aren't harmless. Each one means the heat exchanger got hot enough to trigger a safety shutdown, and chronic overheating is a leading cause of cracked heat exchangers.
Never jumper or bypass a safety switch to get heat. It can cause overheating, flame rollout or carbon monoxide exposure. If a rollout switch has tripped, don't reset it repeatedly. Call a technician.
How we fix it
- Read the code and the history to see which switch is tripping and when.
- Measure draft with a manometer (pressure switch) or temperature rise and static pressure (limit switch).
- Find and fix the cause: clear traps, replace tubing, clear vents, clean the blower, correct airflow.
- Test the switch itself and replace it only if it's faulty, with the exact rated replacement.
Pressure and limit switch repair cost
| Item | Typical cost | Notes |
|---|---|---|
| Condensate trap / tubing clearing | $120 – $300 | Most common pressure-switch fix |
| Pressure switch replacement | $150 – $450 | Exact rated replacement |
| Limit or rollout switch replacement | $150 – $400 | After the cause is fixed |
| Vent pipe clearing or repair | $150 – $500 | Nests, debris, disconnected joints |