Furnace troubleshooting

Why is my furnace leaking water?

Water around a furnace, or dripping through the ceiling from an attic unit, almost always traces back to the condensate system. The fix is usually simple, but the damage can spread fast if you wait.

Quick answer

High-efficiency furnaces and the AC coil above them produce water that drains away through a trap and drain line. When the drain clogs or a condensate pump fails, water overflows. On a standard 80% furnace, water can signal a venting problem that needs prompt attention.

Water coming through a ceiling? Turn the system off at the thermostat, put a bucket and towels under the drip, and if the drywall is bulging, carefully poke a small hole at the lowest point to drain it into the bucket. Then call.

Where furnace water comes from

A high-efficiency (90%+ AFUE) furnace pulls so much heat from its exhaust that water vapor condenses inside, sometimes gallons a day in cold weather. In most Schertz homes, the AC evaporator coil sits on top of the furnace and adds even more water in summer. Both drain through the same system.

The common causes

Clogged drain line

Algae and debris block the line. Texas heat makes this very common. Water backs up into the pan and overflows.

Clogged internal trap

Inside the furnace, the trap fills with residue. It can leak and also cause pressure-switch lockouts.

Failed condensate pump

Where water can't drain by gravity, a small pump lifts it. Stuck floats and burned-out motors cause overflows.

Rusted drain pan or failed float switch

The secondary pan under attic units should catch overflow, and a float switch should shut the system off before it spills.

Venting problem (80% furnaces)

Standard furnaces shouldn't produce liquid water. Water there can mean exhaust is condensing in a poorly sized or sloped flue. See flue & venting.

Humidifier leak

If you have a whole-home humidifier, its water line or drain can leak at the furnace.

A clue many homeowners miss

Many attic systems have a secondary drain line that ends outside, often above a window or under an eave. If water is dripping from that pipe, your primary drain is clogged. The backup is doing its job, but the pan is filling. Call before it overflows.

What you can safely do

  • Turn the system off to stop more water production.
  • Soak up standing water away from electrical parts.
  • Check whether the condensate pump (a small box with tubing, near the furnace) is full or humming.
  • Don't open sealed furnace compartments or try to clear the internal trap yourself.

The repair

A technician clears and flushes the drain lines, cleans and refills the trap, tests or replaces the pump and float switch, and checks the pan. Most condensate repairs cost $120–$400. See condensate drain repair and attic furnace repair.

FAQ

Frequently asked questions

Don't see your question? Call (210) 898-9282.

Is it normal for a furnace to have water?

Water inside a high-efficiency furnace's drain system is normal. Water on the floor, in the secondary pan or through the ceiling is not.

Can I keep using my furnace if it's leaking water?

Turn it off until the cause is fixed. Water can damage electrical components and ceilings, and a clogged trap often causes lockouts anyway.

How do I prevent condensate clogs?

Yearly drain flushing during a tune-up, and a working float switch. Some homeowners also pour white vinegar into the drain access port every few months.